Re: 2 PCCS6 in one system?

From: General Listmanager <General.listmanager@pysdiscussext.py.intel.com>
Date: Tue Mar 23 2004 - 03:37:12 EST

From: DSP K.

-
MTP76.dc2 works fine when MTP3 run on board.
But when I try to set in config.txt as below
LOACL 0x22 *MTP3
FORK_PROCESS mtp_nt -LpC:\septel\mtp76.dc2 -m0x22

I got response "License authorization failed
Error -2 License file corrupted..

My board is PCCS6.

On 3/23/2004 1:21:26 AM, Jan Mlynar wrote:
>When your board is an ISA form
>factor, then yes. You have to
>download
>firmware mtp76.dc2. When your
>board is PCI or cP, then still
>use ss7.dc2
>but
>specifying MTP2 as a
><run_mode> parameter while
>resetting the board. You
>can
>have another kind of troubles,
>because I'm not sure, if you
>can run MTP2
>on
>the board with ISUP (or other
>higher) licence button - in
>that case you w
>ill
>get the message, that your
>licence is not correct.
>
>Jan Mlynar
>
>----- Original Message -----
>From: "General Listmanager"
><General.listmanager@pysdiscus
>sext.py.intel.c
>om>
>To: <Recipients of 'General'
>suppressed>
>Sent: Tuesday, March 23, 2004
>7:16 AM
>Subject: Re: 2 PCCS6 in one
>system?
>
>
>> From: DSP K.
>>
>>
>> Hi Jan,
>>
>> Thank you very much for your kind reply.
>> I am trying to move MTP3 to host but GCTLOAD
>> request another license file for FORK_PROCESS mtp_nt.exe. I have no ide
>al
>about this file. Is MTP76.dc2?
>>
>> Hans
>> ¡@
>>
>> On 3/22/2004 3:31:01 AM, Jan Mlynar wrote:
>> >If you have two Septel boards
>> >in one chasis, you have to use
>> >host based MTP3
>> >and upper layers. So, only
>> >MPT2 should be running on the
>> >board.
>> >
>> >In the case, you don't need
>> >route messages between boards
>> >(on MTP3), there
>> >is possibility to run gctload
>> >twice - one for each board,
>> >but the easier way
>> >in this case is to have single
>> >board in a chasis.
>> >
>> >Jan Mlynar
>> >
>>
>>
>>
>>
>>
>>
>> To reply: mailto:General.27778@pysdiscussext.py.intel.com
>> To start a new topic: mailto:General@pysdiscussext.py.intel.com
>> To login: http://members.support.dialogic.com/wbproxy/wbpx.dll/~general
>>
>>
>>
>>
>
>

-

To reply: mailto:General.27780@pysdiscussext.py.intel.com
To start a new topic: mailto:General@pysdiscussext.py.intel.com
To login: http://members.support.dialogic.com/wbproxy/wbpx.dll/~general
Received on Tue Mar 23 03:48:32 2004