Re: 2 PCCS6 in one system?

From: General Listmanager <General.listmanager@pysdiscussext.py.intel.com>
Date: Tue Mar 23 2004 - 05:55:11 EST

From: Jan Mlynar

This is probably not a problem of the licence button on the board. To run
MTP3 on the host, you need a licence for it.

Jan Mlynar

----- Original Message -----
From: "General Listmanager" <General.listmanager@pysdiscussext.py.intel.c
om>
To: <Recipients of 'General' suppressed>
Sent: Tuesday, March 23, 2004 9:37 AM
Subject: Re: 2 PCCS6 in one system?

> From: DSP K.
>
>
> -
> MTP76.dc2 works fine when MTP3 run on board.
> But when I try to set in config.txt as below
> LOACL 0x22 *MTP3
> FORK_PROCESS mtp_nt -LpC:\septel\mtp76.dc2 -m0x22
>
> I got response "License authorization failed
> Error -2 License file corrupted..
>
> My board is PCCS6.
>
>
>
> On 3/23/2004 1:21:26 AM, Jan Mlynar wrote:
> >When your board is an ISA form
> >factor, then yes. You have to
> >download
> >firmware mtp76.dc2. When your
> >board is PCI or cP, then still
> >use ss7.dc2
> >but
> >specifying MTP2 as a
> ><run_mode> parameter while
> >resetting the board. You
> >can
> >have another kind of troubles,
> >because I'm not sure, if you
> >can run MTP2
> >on
> >the board with ISUP (or other
> >higher) licence button - in
> >that case you w
> >ill
> >get the message, that your
> >licence is not correct.
> >
> >Jan Mlynar
> >
> >----- Original Message -----
> >From: "General Listmanager"
> ><General.listmanager@pysdiscus
> >sext.py.intel.c
> >om>
> >To: <Recipients of 'General'
> >suppressed>
> >Sent: Tuesday, March 23, 2004
> >7:16 AM
> >Subject: Re: 2 PCCS6 in one
> >system?
> >
> >
> >> From: DSP K.
> >>
> >>
> >> Hi Jan,
> >>
> >> Thank you very much for your kind reply.
> >> I am trying to move MTP3 to host but GCTLOAD
> >> request another license file for FORK_PROCESS mtp_nt.exe. I have no
ide
> >al
> >about this file. Is MTP76.dc2?
> >>
> >> Hans
> >> ¡@
> >>
> >> On 3/22/2004 3:31:01 AM, Jan Mlynar wrote:
> >> >If you have two Septel boards
> >> >in one chasis, you have to use
> >> >host based MTP3
> >> >and upper layers. So, only
> >> >MPT2 should be running on the
> >> >board.
> >> >
> >> >In the case, you don't need
> >> >route messages between boards
> >> >(on MTP3), there
> >> >is possibility to run gctload
> >> >twice - one for each board,
> >> >but the easier way
> >> >in this case is to have single
> >> >board in a chasis.
> >> >
> >> >Jan Mlynar
> >> >
> >>
> >>
> >>
> >>
> >>
> >>
> >> To reply: mailto:General.27778@pysdiscussext.py.intel.com
> >> To start a new topic: mailto:General@pysdiscussext.py.intel.com
> >> To login: http://members.support.dialogic.com/wbproxy/wbpx.dll/~gene
ral
> >>
> >>
> >>
> >>
> >
> >
>
>
>
> -
>
>
>
>
>
>
> To reply: mailto:General.27780@pysdiscussext.py.intel.com
> To start a new topic: mailto:General@pysdiscussext.py.intel.com
> To login: http://members.support.dialogic.com/wbproxy/wbpx.dll/~general
>
>
>
>

To reply: mailto:General.27783@pysdiscussext.py.intel.com
To start a new topic: mailto:General@pysdiscussext.py.intel.com
To login: http://members.support.dialogic.com/wbproxy/wbpx.dll/~general
Received on Tue Mar 23 06:05:55 2004